Need an extra hot water unit for your offshore platform or vessel? This rental calorifier has just returned from an offshore platform and is ready to be deployed again at very short notice. It is installed in a sturdy skid and certified for offshore placement (DNV2.7-1). The calorifier is suitable for operation in non-hazardous areas.

Available for rent now: offshore calorifier      

Specifications     

  • Make: Hatenboer-Water     
  • Type Reference: ESSE2000
  • Capacity: 2000 Litres
  • Design code: ASME VIII (not U stamped)
  • Alignment: Vertical
  • Material: Stainless steel 316L
  • Main heating: Electric, 3x440V/60Hz
  • Temperatures secondary: 10-75°C
  • Design temperature secondary:100°C
  • Secondairy Operating/Design Pressure: 6.7~8.2/12.3 barG
  • Dimensions: 1510 mm (L) x 1310 mm (W) x 3303 mm (H)
  • Support: 4 legs incl deck fasting
  • Inspection opening: 450 mm diam (incl david)
  • Connections       
    • in/outlet: 2” ANSI flanged (ASME 16,5, #150)
    • Drain: 1½” ANSI flanged (ASME 16,5, #150)
    • PSV connection: 1” ANSI flanged (ASME 16,5, #150)
    • Instrument connections: BSPF thread
  • Surface preparation: Pickled & passivated (not coated)       
  • Insulation: 50 mm thick foil mineral wool
  • Outer casing (cladding): stucco aluminium, not coated
  • Third party design appraisal: ABS , based on ASME VIII, incl. stage inspection
  • NR13 document file included

Built-in electric heating:    

  • Type: Immersion heaters, removable

  • Capacity: 33 - 300kW at 3x440V/60Hz 

  • Elements: Incoloy/brass

  • Protection degree: IP56

Accessories     

  • Safety relief valve, 1” in/1,5”out, 9 bar
  • Pressure gauge
  • Temperature gauge
  • Low water probe
  • Pt100 sensor
  • Drain valve & hose union
  • Control & high limit sensors
  •  In-outlet isolation valves
  •  Outlet check valve     
  • Cables: un-armoured                         

Calorifier Electrical Cabinet       

  • Type: Loose supplied (including interconnecting cabling)
  • Material: coated sheet steel RAL 7032
  • Control: 9 staged
  • Complete with:                                        
    • Main switch
    • Indication lamps for control power, heater on/off, alarm            
    • Lamp test
    • Common alarm connection
    • Stage indicators
    • Low water protection                         
    • Protection degree: IP54
  • Wiring: including wire numbering
  • Cable glands: LSH/F Hawk
  • Dimensions: 1200 x 1200 x 300 mm

Offshore lifting frame     

  • Design: according to DNV2.7-1 & EN 12079-1
  • Certified by: LRS
  • Material: S355J2
  • Certificates: 3.1
  • Coating:acc to offshore spec
  • Hoisting sling: included (DNV2.7-1 certified)
  • Load test: 1,5xMWG incl. makers load test certificate